Перевод: с немецкого на все языки

со всех языков на немецкий

maximum current

  • 1 unabhängig verzögerter Überstromauslöser

    1. максимальный расцепитель тока с независимой выдержкой времени

     

    Максимальное реле или максимальный расцепитель тока с независимой выдержкой времени
    Максимальное реле или максимальный расцепитель тока, срабатывающие с определенной выдержкой времени, которая может регулироваться, но не зависит от величины сверхтока.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    EN

    definite time-delay over-current release
    an over-current release which operates with a definite time-delay, which may be adjustable, but is independent of the value of the over-current
    [IEV number 441-16-34]

    FR

    déclencheur à maximum de courant à retard indépendant
    déclencheur à maximum de courant qui fonctionne avec un retard défini qui peut être réglable mais est indépendant de la valeur de la surintensité.
    [IEV number 441-16-34]

    Параллельные тексты EN-RU

    Protection against overload may be provided on both the high-voltage side and the low-voltage side, depending on the transformer power. For low-power transformers the protection should be positioned on the low-voltage side, while for high-power transformers the protection should be provided on the high-voltage side. Protection against overloads on the HV side is provided using HV circuit breakers associated with maximum-current protections in constant time or independent time.
    [Legrand]

    В зависимости от мощности трансформатора, защита от перегрузки выполняется на стороне высшего или низшего напряжения. Мощные трансформаторы защищают со стороны электросети, а маломощные – со стороны нагрузки. Защита от перегрузки на стороне высшего напряжения осуществляется высоковольтным автоматическим выключателем с максимальными расцепителями тока с независимой выдержкой времени.
    [Перевод Интент]

    Недопустимые, нерекомендуемые

    Тематики

    Классификация

    >>>

    EN

    DE

    FR

    Немецко-русский словарь нормативно-технической терминологии > unabhängig verzögerter Überstromauslöser

  • 2 Grenzstrom(stärke) (eines Zählers)

    1. максимальный ток

    1

     

    максимальный ток
    наибольшее значение тока, при котором счетчик удовлетворяет требованиям настоящего стандарта в отношении точности.
    [ ГОСТ 6570-96]


    2

     

    максимальный ток
    -
    [IEV number 314-07-03]

    EN

    maximum current
    highest value of current at which a meter meets the specified accuracy requirements
    [IEV number 314-07-03]

    FR

    courant maximal
    valeur la plus grande pour laquelle un compteur est censé satisfaire aux prescriptions d’exactitude spécifiées
    [IEV number 314-07-03]


    Тематики

    EN

    DE

    FR

    • courant maximal valeur la plus grande pour laquelle un compteur est censé satisfaire aux prescriptions d’exactitude spécifiées [IEV number 314-07-03]

    Немецко-русский словарь нормативно-технической терминологии > Grenzstrom(stärke) (eines Zählers)

  • 3 Kurzschlussstrom (einer Zelle oder Batterie), m

    1. ток короткого замыкания химического источника тока

     

    ток короткого замыкания химического источника тока
    ток короткого замыкания

    Максимальное значение тока разряда химического источника тока при коротком замыкании внешней цепи.
    [ ГОСТ 15596-82]

    ток короткого замыкания
    Максимальный ток, отдаваемый батареей в цепь с минимальным сопротивлением по сравнению с сопротивлением батареи в заданных условиях.
    [Инструкция по эксплуатации стационарных свинцово-кислотных аккумуляторных батарей в составе ЭПУ на объектах ВСС России. Москва 1998 г.]

    EN

    short-circuit current (related to cells or batteries)
    maximum current which should be delivered by a cell or battery into an external circuit with zero electric resistance, or an external circuit which depresses the cell or battery voltage to approximately zero volt
    NOTE – Zero electric resistance is a hypothetical condition and in practice the short-circuit current is the peak current flowing in a circuit of very low resistance compared to the internal resistance of the battery.
    [IEV number 482-03-26 ]

    FR

    courant de court-circuit (d’un élément ou d’une batterie), m
    courant maximal que pourrait fournir un élément ou une batterie dans un circuit extérieur de résistance électrique nulle, ou un circuit extérieur qui abaisse la tension aux bornes de l’élément ou de la batterie approximativement à zéro volt
    NOTE – Une résistance électrique nulle est hypothétique et en pratique, le courant de court-circuit est le courant de crête circulant à travers un circuit de résistance très faible par rapport à la résistance interne de la batterie.
    [IEV number 482-03-26 ]

    Тематики

    Классификация

    >>>

    Синонимы

    EN

    DE

    • Kurzschlussstrom (einer Zelle oder Batterie), m

    FR

    • Kurzschlussstrom (einer Zelle oder Batterie), m

    Немецко-русский словарь нормативно-технической терминологии > Kurzschlussstrom (einer Zelle oder Batterie), m

  • 4 Zählertyp

    1. тип счетчика

    1

     

    тип счетчика
    термин, используемый для определения совокупности конкретной конструкции счетчика, имеющей:
    а) сходные метрологические характеристики;
    б) конструктивное подобие элементов, определяющих эти характеристики.
    Тип может иметь несколько значений номинального тока и номинального напряжения.
    Счетчики обозначаются изготовителем одной или большим числом групп букв или цифр, или комбинацией букв и цифр. Каждый тип имеет только одно обозначение.
    Примечание - Данный тип представляют один или несколько образцов счетчиков, предназначенных для проведения испытаний для целей утверждения типа, характеристики которых (номинальные токи и номинальные напряжения) соответствуют значениям, указанным изготовителем.
    [ ГОСТ 6570-96]


    2

     

    тип счетчика
    -
    [IEV number 314-07-07]

    EN

    meter type
    particular design of meter, manufactured by one manufacturer, having:
    a) similar metrological properties;
    b) the same uniform construction of parts determining these properties;
    c) the same ratio of the maximum current to the reference current
    NOTE 1 – The type may have several values of reference current and reference voltage.
    NOTE 2 – Meters are designated by the manufacturer by one or more groups of letters or numbers, or a combination of letters and numbers. Each type has one designation only.
    NOTE 3 – The type is represented by the sample meter(s) intended for the type tests and whose characteristics (reference current and reference voltage) are chosen from the values given in the tables proposed by the manufacturer.
    [IEV number 314-07-07]

    FR

    type
    ensemble des compteurs fabriqués par un même constructeur et ayant:
    a) des qualités métrologiques similaires;
    b) l’uniformité constructive des constituants déterminant ces qualités;
    c) un même rapport entre courant maximal et courant de référence
    NOTE 1 – Le type peut comporter différentes valeurs de courant de référence et de tension de référence.
    NOTE 2 – Les compteurs sont désignés par le constructeur, par une ou plusieurs associations soit de lettres, soit de chiffres. A chaque type correspond une seule désignation.
    NOTE 3 – Le type est représenté par le ou les compteurs échantillons destinés aux essais de type et dont les caractéristiques (courant de référence et tension de référence) sont choisies parmi celles figurant dans les tableaux proposés par le constructeur.
    [IEV number 314-07-07]

    Тематики

    EN

    DE

    FR

    Немецко-русский словарь нормативно-технической терминологии > Zählertyp

  • 5 Spitzenstrom

    m <el> ■ peak current; maximum current
    m <el.chem> ■ peak current

    German-english technical dictionary > Spitzenstrom

  • 6 Strombelastbarkeit

    f <el> (von Leitungen, Komponenten) ■ current-carrying capacity; carrying capacity; current rating; maximum current load

    German-english technical dictionary > Strombelastbarkeit

  • 7 Höchststrom

    m <el> ■ maximum current; peak current

    German-english technical dictionary > Höchststrom

  • 8 Scheitelwert des Stroms

    Scheitelwert m des Stroms peak value of current, maximum current

    Deutsch-Englisch Wörterbuch der Elektrotechnik und Elektronik > Scheitelwert des Stroms

  • 9 Maximalrelais

    n <el> ■ overcurrent relay; overload relay; maximum-current circuit breaker; overcurrent circuit breaker; overload switch

    German-english technical dictionary > Maximalrelais

  • 10 Maximalschalter

    m <el> ■ overcurrent relay; overload relay; maximum-current circuit breaker; overcurrent circuit breaker; overload switch

    German-english technical dictionary > Maximalschalter

  • 11 Maximalstrom

    m <el> ■ maximum current

    German-english technical dictionary > Maximalstrom

  • 12 Höchstnennstrom

    Höchstnennstrom m maximum current rating

    Deutsch-Englisch Wörterbuch der Elektrotechnik und Elektronik > Höchstnennstrom

  • 13 Maximalrelais

    Maximalrelais n maximum (current) relay, overcurrent relay

    Deutsch-Englisch Wörterbuch der Elektrotechnik und Elektronik > Maximalrelais

  • 14 Maximalschalter

    Maximalschalter m maximum current circuit breaker, overload switch

    Deutsch-Englisch Wörterbuch der Elektrotechnik und Elektronik > Maximalschalter

  • 15 Maximalstrom

    Maximalstrom m maximum current

    Deutsch-Englisch Wörterbuch der Elektrotechnik und Elektronik > Maximalstrom

  • 16 Überstromrelais

    Überstromrelais n overcurrent [overload, maximum current] relay

    Deutsch-Englisch Wörterbuch der Elektrotechnik und Elektronik > Überstromrelais

  • 17 Übernahmestrom

    1. ток пересечения IB
    2. ток пересечения
    3. ток координации

     

    ток координации
    Токовая координата точки пересечения время-токовых характеристик двух устройств для защиты от сверхтоков.
    МЭК 60050(441-17-16).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]


    ток координации (Iв)
    Координата точки пересечения время-токовых характеристик наибольшей отключающей способности двух аппаратов защиты от сверхтоков.
    Примечания
    1 Ток координации — предельное значение тока, выше которого при наличии двух последовательно соединенных аппаратов защиты от сверхтоков защитный аппарат, расположенный со стороны питания, как правило, но не обязательно обеспечивает резервную защиту второго защитного аппарата
    2 Вместо время-токовых характеристик можно использовать характеристики I2t
    [ ГОСТ Р 50345-99( МЭК 60898-95)]

    EN

    take-over current
    the current co-ordinate of the intersection between the time-current characteristics of two over-current protective devices
    [IEV number 441-17-16]

    FR

    courant d'intersection
    valeur du courant correspondant à l'intersection des caractéristiques temps-courant de deux dispositifs de protection à maximum de courant
    [IEV number 441-17-16]

    Тематики

    EN

    DE

    FR

     

    ток пересечения
    -
    [IEV number 442-05-61]

    EN

    take-over current
    the current co-ordinate of the intersection between the maximum break time-current characteristics of two overcurrent protective devices
    Source: 441-17-16 MOD
    [IEV number 442-05-61]

    FR

    courant d'intersection
    coordonnées du courant de l'intersection entre les caractéristiques de durée maximale de coupure temps-courant de deux dispositifs de protection à maximum de courant
    Source: 441-17-16 MOD
    [IEV number 442-05-61]

    Тематики

    • электротехника, основные понятия

    EN

    DE

    FR

     

    ток пересечения IB
    -
    [IEV number 442-05-61]

    EN

    take-over current
    the current co-ordinate of the intersection between the maximum break time-current characteristics of two overcurrent protective devices
    [IEV number 442-05-61]

    FR

    courant d'intersection
    coordonnées du courant de l'intersection entre les caractéristiques de durée maximale de coupure temps-courant de deux dispositifs de protection à maximum de courant
    [IEV number 442-05-61]

    Тематики

    Синонимы

    • IB

    EN

    DE

    FR

    Немецко-русский словарь нормативно-технической терминологии > Übernahmestrom

  • 18 Dauerstrombelastbarkeit, f

    1. длительный допустимый ток

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Немецко-русский словарь нормативно-технической терминологии > Dauerstrombelastbarkeit, f

  • 19 Strombelastbarkeit, f

    1. длительный допустимый ток

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Немецко-русский словарь нормативно-технической терминологии > Strombelastbarkeit, f

  • 20 Überstromselektivität

    1. селективность по сверхтокам

     

    селективность по сверхтокам
    Координация рабочих характеристик двух или нескольких устройств для защиты от сверхтоков с таким расчетом, чтобы в случае возникновения сверхтоков в пределах указанного диапазона срабатывало только устройство, предназначенное для оперирования в данном диапазоне, а прочие не срабатывали.
    Примечание. Различаются последовательная селективность, когда через различные устройства для защиты от сверхтоков проходит практически одинаковый сверхток, и параллельная селективность, когда через тождественные защитные устройства проходят различные доли сверхтока.
    МЭК 60050(441-17-15).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    селективность при сверхтоке
    Координация соответствующих характеристик двух или более устройств для защиты от сверхтоков с таким расчетом, чтобы при появлении сверхтоков в установленных пределах срабатывало устройство, рассчитанное на эти пределы, в то время как другое (ие) устройство (а) не срабатывало (и).
    [ ГОСТ Р 50339. 0-2003 ( МЭК 60269-1-98)]

    селективность при сверхтоке предохранителей

    Координация соответствующих характеристик двух или нескольких предохранителей, или предохранителей и других защитных устройств, обеспечивающая при появлении сверхтоков, находящихся в данных пределах, состояние срабатывания предохранителя, предусмотренного для срабатывания в этих пределах, тогда как другие предохранители не срабатывают.
    [ ГОСТ 17242-86]

    EN

    over-current discrimination
    co-ordination of the operating characteristics of two or more over-current protective devices such that, on the incidence of over-currents within stated limits, the device intended to operate within these limits does so, while the other(s) does (do) not
    NOTE Distinction is made between series discrimination involving different over-current protective devices passing substantially the same over-current and network discrimination involving identical protective devices passing different proportions of the over-current.
    [IEV 441-17-15]

    FR

    sélectivité lors d'une surintensité
    coordination entre les caractéristiques de fonctionnement de plusieurs dispositifs de protection à maximum de courant de telle façon qu'à l'apparition de surintensités comprises dans des limites données, le dispositif prévu pour fonctionner entre ces limites fonctionne, tandis que le ou les autres ne fonctionnent pas
    NOTE On distingue la sélectivité série réalisée par différents dispositifs de protection à maximum de courant soumis pratiquement à la même surintensité et la sélectivité de réseau réalisée par des dispositifs de protection à maximum de courant identiques soumis à des fractions différentes de la surintensité
    [IEV 441-17-15]

    Параллельные тексты EN-RU

    Discrimination Method

    Appropriate when downstream CB is capable of 100% fault current break within the entire range of protection.


    [LS Industrial Systems]

    Селективность по сверхтокам

    Данный метод применяется в том случае, когда автоматический выключатель, расположенный со стороны нагрузки, может
    в течение времени срабатывания выдержать 100 % тока короткого замыкания.

    [Перевод Интент]

    Тематики

    EN

    DE

    FR

    Немецко-русский словарь нормативно-технической терминологии > Überstromselektivität

См. также в других словарях:

  • maximum current — didžiausioji srovė statusas T sritis Standartizacija ir metrologija apibrėžtis Didžiausias srovės stipris, kuriam esant elektros skaitiklis dar atitinka norminius tikslumo reikalavimus. atitikmenys: angl. maximum current vok. Maximalstrom, m rus …   Penkiakalbis aiškinamasis metrologijos terminų žodynas

  • maximum current breaker — didžiausiosios ribinės srovės išjungiklis statusas T sritis radioelektronika atitikmenys: angl. maximum current breaker; overcurrent circuit breaker vok. Überstromschalter, m; Überstromschutzschalter, m rus. автомат максимального тока, m pranc.… …   Radioelektronikos terminų žodynas

  • Current limiting — is the practice in electrical or electronic circuits of imposing an upper limit on the current that may be delivered to a load with the purpose of protecting the circuit generating or transmitting the current from harmful effects due to a short… …   Wikipedia

  • Current density — This page is about the electric current density in electromagnetism. For the probability current density in quantum mechanics, see Probability current. Current density is a measure of the density of flow of a conserved charge. Usually the charge… …   Wikipedia

  • Maximum power point tracking — Current voltage characteristics of a solar cell at a particular light level, and in darkness. The area of the yellow rectangle gives the output power. Pmax denotes the maximum power point Maximum power point tracking (MPPT) is a technique that… …   Wikipedia

  • Maximum Fighting Championship — Type Private Industry Mixed martial arts promotion Founded 2001 Founder(s) …   Wikipedia

  • Current Issues and Events — (commonly known as Current Events) is one of several academic events sanctioned by the University Interscholastic League. The contest began in the 1990 91 scholastic year.Current Events is designed to test students knowledge and understanding of… …   Wikipedia

  • Maximum parsimony — Maximum parsimony, often simply referred to as parsimony, is a non parametric statistical method commonly used in computational phylogenetics for estimating phylogenies. Under maximum parsimony, the preferred phylogenetic tree is the tree that… …   Wikipedia

  • Maximum PC — September 2010 cover Editor in Chief George Jones Categories Computing Frequency Monthly Total …   Wikipedia

  • Maximum-Football — Cover art Developer(s) Wintervalley Software Publisher(s) Matrix Games …   Wikipedia

  • Maximum Destruction — ost the Monster Jam in Stafford Springs, CT Owner and Driver Information Owner Tom Meents Driver(s) Tom Meents and Neil Elliott Home …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»